Product manual

1 Surfaces
Substrates must be clean and capable of bearing loads. Illbruck PU700 has excellent adhesion to both wet and dry surfaces.

4 Cleaning
For cleaning of the gun, use illbruck gun-cleaner. Follow the instructions for use on the canister or check the illbruck gun cleaner datasheet.

2 Preparation
Shake the illbruck PU700 canister vigorously at least 20 times before use, and again periodically during application. Remove the protective cap and screw the gun carefully onto the canister.


   

5 Storage and transport
Store between + 5°C and +25°C in dry conditions upright and in original packaging. If not stored upright, there is a possibility that the valve will become sealed. This is not possible when the canister is screwed onto the applicator gun.

   
3 Apply PU700 brick adhesive
The amount of adhesive can be regulated by pulling the trigger or adjusting the regulation screw on the gun. After a couple of seconds the adhesive will form a thin layer. A bead of approx. 4cm to 5cm is recommended to achieve a strong bond on bricks 7cm to 20cm width. For larger block widths, please contact us.

   

6 Important recommendations:
Use only in well-ventilated areas. No smoking. Wear suitable eye protection, gloves and working clothes. Protect floor coverings with paper or a plastic foil. Remove fresh foam immediately with illbruck Gun-/Spraycleaner or illbruck cleaning towels. Cured foam can only be removed mechanically.